Enquiries
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>
Huawei Indoor Integrated Intelligent Site provides stable, reliable power to Radio Access Network (RAN), fixed network, aggregation room, Central Office (CO) room, and enterprise telecom sites. An indoor DC power system, it features a standalone or integrated design, an industry-leading 97% rectifier module, and rated output capacity from 200 A to 3000 A.
• High-density power and BoostLi, offering over 2x the capacity with the same footprint
• All-modular design, PSU, power distribution, and BoostLi smooth evolution
• Unified eMIMO power platform, all-mode output for all equipment
• Unified energy OSS system, remote management for all sites, improved O&M efficiency
• AI scheduling for solar/grid/diesel generator energy input maximizes site power efficiency
• Precise load metering, control, and backup
• Wide voltage range of 85 V to 300 V for rectifier module. 500 V high voltage resistance enables operation in harsh grid environments
• It can be used in all kinds of harsh grid environments because of its 500V high voltage resistance
• A 100 A rectifier can work with 50% of rated power with phase loss.
• PSU/BoostLi N + 1 backup, hot swappable, zero service interruptions for spare replacement
Parameters | TPB Small Capacity Power | TPB Large Capacity Power |
Dimensions (H x W x D) |
2000 x 600 x 600 mm (Integrated) 1600 x 600 x 400 mm (Combined) 546 x 442 x 360 mm (Mini) |
2000 x 600 x 600 mm |
Weight | 20 kg to 120 kg | 120 kg to 180 kg |
Protection Rating |
IP20 | IP20 |
User Space | 0U to 16U | None |
Input Mode | 220V/380V three-phase four-wire, 110V dual-live wire/three-live wire |
Three-phase five-wire (L1, L2, L3, N, and PE) three-phase four-wire (L1, L2, L3, and PE) |
Maximum Output Current | 200 A to 600 A |
1200 A to 3000 A |
Operating Temperature | –10℃ to 45℃ |
–10℃ to 45℃ |
Storage/Transport Temperature | –40℃ to 70℃ |
–40℃ to 70℃ |
Operating Humidity | 5% to 95% (non-condensing) | 5% to 95% (non-condensing) |
Altitude | 0 m to 4000 m (when the altitude ranges from 3000 m to 4000 m, the operating temperature decreases by 1ºC for each additional 200 m) |
0 m to 4000 m (when the altitude ranges from 3000 m to 4000 m, the operating temperature decreases by 1ºC for each additional 200 m) |
Cooling Mode | Natural cooling | Natural cooling |
Are you a Huawei partner? Log in to see additional resources. Looking for a solution from a Huawei partner? Connect with our partner ecosystem.